Textile Engineering / Textile Thermal Resistance & Clo
FREE TO EXPLORE
LABORATORY 30 · TEXTILE ENGINEERING

Thermal Insulation Resistance (Rct) & Clo Value: Guarded Hotplate Method

Determine the dry thermal insulation resistance (Rct in m²·K/W) and clo value of insulating nonwovens and cold-weather clothing using an automated sweating guarded hotplate (skin model). Explore interactive textile simulation, yarn mechanics, and fabric physical testing.

YARN SCIENCE · WEAVING & KNITTING · WET PROCESSING · FABRIC COMFORT · TRIBOLOGY · TECHNICAL TEXTILES

Your virtual textile engineering laboratory.

THERMAL INSULATION RESISTANCE R_CT—
CONDITIONED TEXTILE TELEMETRY (20 °C, 65% RH)

Ready to sample with Batt Thickness = 15.0 mm.

15.0 mm
Conditioned per ISO 139 standard atmosphere (20.0 °C, 65.0% RH).

Adjust Batt Thickness, then execute textile test acquisition.

Textile measurements are captured using precision transducers and 64-bit IEEE 754 floating-point logging under standard temperature and humidity. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support comprehensive fiber, yarn, and fabric structural evaluation.

Textile engineering continuum and boundary limits

All fiber bundles, yarns, and fabric specimens are evaluated under standardized pre-tension and standard atmosphere (20 °C, 65% RH per ISO 139). Linear constitutive models reflect small-strain elasticity and uniform dye diffusion kinetics.

Laboratory apparatus & testing equipment.

Textile Thermal Resistance & Clo Workstation Frame

Provides rigid calibrated clamping, standardized geometry, and environmental control for trapped dead air pockets, conduction vs radiation, clo unit equivalence.

Digital Load Cell & S-Beam Micro-Force Transducer (Class 0.5)

Measures tensile breaking force, bursting pressure, or frictional drag with ±0.05% baseline accuracy.

Linear Variable Differential Transformer (LVDT) & Optical Extensometer

Quantifies minute fiber extensions, fabric deflections, and liquid meniscus rise with 0.001 mm resolution.

Multi-Channel Digital Telemetry Data Logger & Conditioning Unit

Samples force bridge signals, displacement sensors, optical reflectance, and temperature/RH probes at 1 kHz.

Standard Atmosphere Climate Conditioning Chamber (20 °C, 65% RH)

Conditions textile specimens to moisture equilibrium per ISO 139 before establishing batt thickness setpoints.

Four-Terminal Shielded Lead Wiring & Grounded Sensor Cabling

Eliminates thermal EMF drift, electrical contact resistance errors, and ambient acoustic noise.

FOLLOW THE METHOD

A reason behind every step.

Determine the dry thermal insulation resistance (Rct in m²·K/W) and clo value of insulating nonwovens and cold-weather clothing using an automated sweating guarded hotplate (skin model). Standardized parameter settings: 5.0, 10.0, 15.0, 20.0, 25.0, 30.0 mm.

  1. Specimen Conditioning & Atmospheric Equilibration: Condition all textile test specimens in the standard conditioning room at 20.0 ± 2.0 °C and 65.0 ± 4.0% relative humidity for a minimum of 24 hours per ISO 139.
  2. Visual Inspection & Apparatus Zero Tare: Inspect all mechanical grips, pneumatic clamps, optical mirrors, and electronic load cells. Execute zero tare balance on digital indicators and calibrate displacement gauges.
  3. Initial Gauge Alignment & Clamping Pre-Tension: Mount the specimen securely between jaws or on the test platform. Apply standardized pre-tension to eliminate slack and align the batt thickness with the primary zero datum.
  4. Systematic Parameter Variation & Acquisition: Increment the batt thickness systematically across the designated range (5.0 to 30.0 mm), permitting full mechanical or chemical stabilization at each test increment.
  5. Multi-Sensor Telemetry & Signal Logging: Record the primary dependent variable (Thermal Insulation Resistance R_ct) alongside auxiliary channel telemetry. Verify linear proportionality and signal stability before advancing.
  6. Controlled De-Energization & Data Archival: Release all mechanical clamping loads smoothly to zero, de-energize primary drives, secure moving linkages, and export all digital telemetry observations to the persistent laboratory notebook.
YOUR NOTEBOOK · 0 OBSERVATIONS

Turn measurements into textile engineering insight.

See a complete example report ↗

Points are your recorded observations. The solid regression line validates Textile Thermal Resistance & Clo mathematical scaling.

LINEAR REGRESSION FIT · y = mx + b
R_ct = 0.0240 · t
#Insulating Batt Thickness t (mm)Thermal Insulation Resistance R_ct (m²·K/W)Insulating batt thickness t (mm)Thermal resistance R_ct (m²·K/W)

No readings yet. Execute a textile trial and record it.

CHECK YOUR UNDERSTANDING

Explain what the textile engineering metrics mean.

Question 1: In the experimental study of Textile Thermal Resistance & Clo, the primary dependent variable measured is:

Question 2: The governing mathematical constitutive equation for Textile Thermal Resistance & Clo is modeled as:

Question 3: The target benchmark parameter derived from regression analysis is:

Question 4: What standard testing atmosphere is globally specified for physical textile testing per ISO 139?

THEORY AND FIBER-FABRIC CONTEXT

Textile Engineering background & physical principles.

Determine the dry thermal insulation resistance (Rct in m²·K/W) and clo value of insulating nonwovens and cold-weather clothing using an automated sweating guarded hotplate (skin model).

R_ct = 0.0240 · t

Textile engineering principles build upon polymer morphology, yarn structural mechanics, weave/knit topology, and surface transport thermodynamics.