5.000 V DC step source
Provide a constant applied voltage E from t = 0.
Determine the charging time constant of an RC circuit from capacitor-voltage observations and a logarithmic graph. Explore a virtual apparatus, collect readings and analyse a graph.
Ready for a virtual observation.
Adjust the apparatus, then take a reading.
Readings are generated by an ideal model. The diagram is schematic and is not to scale.
The model uses E = 5.000 V, R = 10,000 Ω and C = 100 μF, with zero initial voltage, instantaneous source switching, exact elapsed times and no leakage, equivalent series resistance, dielectric absorption or meter loading. Vc is rounded to 0.001 V. Each requested observation starts an identical transient. The unweighted logarithmic fit treats times as exact and does not model the voltage-dependent uncertainty introduced by transformation. The generator calculates Vc = 5[1 − exp(−t/1.000)] V and rounds to 0.001 V. Analysis uses x = t and y = ln[5/(5 − Vc)], estimating τ = 1/gradient. The reference 1.000 s is the product of the fixed model R and C, not a measurement of actual components.
Provide a constant applied voltage E from t = 0.
Limit charging current and set the resistance in the model time constant.
Store charge; preserve polarity and voltage rating when using a physical polarized capacitor.
Start charging from an initially discharged state and sample capacitor voltage with adequate time resolution.
Determine the charging time constant of an RC circuit from capacitor-voltage observations and a logarithmic graph. Suggested independent settings: 0.2, 0.6, 1, 1.8, 2.6 s.
With a physical source disconnected, discharge through a suitable resistor and verify near-zero capacitor voltage. Check component polarity and ratings before wiring.
The model solution requires Vc(0) = 0 and safe physical handling requires controlled discharge.
Use E = 5.000 V and identify t = 0 as the start of the applied voltage step. Choose a recording method suited to a roughly one-second transient.
A time-origin error changes the transformed intercept.
Choose an elapsed time in the 0.2–3.0 s range and request the capacitor-voltage observation. Record Vc in volts and time in seconds.
The measured quantity is capacitor voltage, not resistor voltage.
Collect at least five distinct times across the range. Each model observation restarts the same initially discharged transient; real repeat runs require a verified discharge first.
A common initial condition makes measurements comparable.
Check that Vc is below E. Calculate E − Vc, then the dimensionless ratio E/(E − Vc), then its natural logarithm. Fit this logarithm against time.
The positive logarithm yields a positive slope equal to 1/τ.
Use τ = 1/m in seconds. Compare with RC = 1.000 s, inspect the intercept and residuals, and discuss voltage-dependent transformed uncertainty and timing calibration.
Agreement with model components is a consistency check rather than independent proof of their accuracy.
Points are your observations. The fit uses SI x and y values before display scaling.
| # | Elapsed charging time t (s) | Capacitor voltage Vc (V) | Elapsed time t (s) | ln[E/(E − Vc)] | Remove |
|---|
No readings yet. Take a virtual measurement and record it.