Instrumented Charpy Pendulum Impact Tester
Calibrated 300 J capacity pendulum with 2 mm radius striker tup and digital optical encoder.
Determine the impact absorbed energy (K_V) and ductile-to-brittle transition temperature (DBTT) of structural bridge steel under high-strain-rate impact loading according to ASTM E23 / BS EN ISO 148-1. Explore interactive structural mechanics, materials simulation, and civil engineering telemetry.
Ready to sample with Temperature = 10.0 °C.
Adjust Temperature, then execute civil engineering measurement.
Civil engineering telemetry is evaluated rigorously using 64-bit IEEE 754 precision. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support high-fidelity structural mechanics and geotechnical continuum modeling.
The civil engineering physical models apply within the specified calibrated operational window (-30.0 to 50.0 °C). ASTM A572 Grade 50 (345 MPa) structural steel. Linearized model over the transition zone relates absorbed energy K_V directly to temperature T with sensitivity 0.8500 J/°C and 0 °C intercept 65.0 J.
Calibrated 300 J capacity pendulum with 2 mm radius striker tup and digital optical encoder.
Hardened tool steel support anvils spaced at 40.0 mm span with 1.0 mm radius corners.
Liquid nitrogen / ethanol cryo-bath and heated bath maintaining -50 °C to +100 °C to ± 0.5 °C.
Specialized tongs transferring specimen from thermal bath to anvil in < 5 seconds per ASTM E23.
Verifies 45° ± 1° notch angle, 2.00 ± 0.05 mm notch depth, and 0.25 mm root radius.
Examines percentage shear fracture lip area versus flat cleavage area on fracture faces.
Determine the impact absorbed energy (K_V) and ductile-to-brittle transition temperature (DBTT) of structural bridge steel under high-strain-rate impact loading according to ASTM E23 / BS EN ISO 148-1. Standardized parameter settings: -30.0, -10.0, 10.0, 30.0, 50.0 °C.
Inspect 10 x 10 x 55 mm steel specimens on the optical projector; verify notch depth (2.00 mm), notch radius (0.25 mm), and 45° angle.
Immerse specimens in the liquid bath at target temperatures (-30, -10, +10, +30, and +50 °C); condition for at least 10 minutes to achieve uniform core temperature.
Latch pendulum hammer at standard initial angle (300 J potential energy); release with empty anvils to record zero-friction windage loss calibration.
Using chilled tongs, remove specimen from bath and place on testing anvils centered with notch facing away from striker tup within strictly 5.0 seconds.
Immediately trip the pneumatic pendulum release latch; allow hammer to sever the specimen and swing through; engage automatic mechanical brake.
Read absorbed energy K_V in Joules from digital encoder; measure lateral expansion at notch root with micrometer gauge; determine percentage shear area.
Points are your recorded observations. The solid regression line validates Charpy Impact Toughness mathematical scaling.
| # | Specimen Temperature T (°C) | Absorbed Impact Energy K_V (J) | Test temperature T (°C) | Absorbed impact energy K_V (J) | Remove |
|---|
No readings yet. Execute a civil engineering trial and record it.
Catastrophic brittle fractures of steel structures—such as the infamous WWII Liberty ship fractures and civil bridge collapses in sub-zero winter temperatures—revealed that static tensile yield strength is insufficient to guarantee structural safety under dynamic shock loading. Body-centered cubic (BCC) ferritic structural steels undergo a profound transformation from ductile, high-energy plastic tearing at warm temperatures to brittle, low-energy transgranular cleavage fracture at freezing temperatures. Standardized under ASTM E23 and ISO 148-1, the Charpy V-notch (CVN) impact test utilizes a standardized square specimen (10 x 10 x 55 mm) with a precision 45° V-notch machined to a depth of 2 mm and root radius of 0.25 mm. The specimen is supported as a simple beam and struck on the face opposite the notch by a calibrated heavy swinging pendulum with striking energy of 300 ± 10 J at impact velocity ~5.2 m/s. The energy absorbed in fracturing the specimen (K_V) is evaluated directly from the difference between pendulum initial release height and post-fracture follow-through height. In this laboratory, impact toughness is tested across temperatures from -30 °C to +50 °C to evaluate impact sensitivity and ensure compliance with AASHTO bridge fracture-critical specifications (minimum 27 J at -20 °C).
ASTM A572 Grade 50 (345 MPa) structural steel. Linearized model over the transition zone relates absorbed energy K_V directly to temperature T with sensitivity 0.8500 J/°C and 0 °C intercept 65.0 J.