Gasketed Plate-and-Frame Heat Exchanger
10-plate pack of 316 stainless steel plates (0.6 mm thick, chevron angle 60°, area 0.240 m^2).
Determine the overall heat transfer coefficient U and thermal effectiveness of a gasketed plate-and-frame heat exchanger as a function of process stream velocity, evaluating the chevron corrugation enhancement factor. Explore interactive transport phenomena, unit operations simulation, and chemical engineering telemetry.
Ready to sample with Velocity v_p = 0.3 m/s.
Adjust Velocity v_p, then execute chemical process trial.
Chemical and process engineering telemetry is evaluated rigorously using 64-bit IEEE 754 precision. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support high-fidelity transport phenomena and unit operations modeling.
The transport and thermodynamic models apply within the specified calibrated operating window (0.1 to 0.6 m/s). Evaluated using a 10-plate stainless steel PHE (plate width 100 mm, length 300 mm, chevron angle β = 60°, total active area A = 0.240 m^2). Linear regression models U versus (v_p)^0.65.
10-plate pack of 316 stainless steel plates (0.6 mm thick, chevron angle 60°, area 0.240 m^2).
Delivers hot process water at 55.0 ± 0.1 °C with variable-speed gear metering pump.
Maintains constant utility flow rate of 10.0 L/min at 15.0 ± 0.1 °C across cold channels.
Measures hot inlet/outlet and cold inlet/outlet manifold temperatures with 0.02 °C accuracy.
Meters hot process flow rate to compute mean inter-plate channel velocity v_p with 0.2% accuracy.
Measures hydraulic pressure drop across hot and cold plate channels from 0 to 100 kPa.
Determine the overall heat transfer coefficient U and thermal effectiveness of a gasketed plate-and-frame heat exchanger as a function of process stream velocity, evaluating the chevron corrugation enhancement factor. Standardized parameter settings: 0.1, 0.2, 0.3, 0.4, 0.5, 0.6 m/s.
Verify plate pack compression dimension tightening bolts to manufacturer specification (tightening dimension A = 32.0 mm); pressurize with water to check gasket seals.
Circulate hot water at 55.0 °C and cold water at 15.0 °C for 15 minutes to purge air and achieve thermal equilibrium.
Adjust process pump speed to establish mean channel velocity v_p = 0.10 m/s; monitor temperature stability for 120 seconds.
Record all four terminal temperatures, calculate thermal duty q_h and q_c, and confirm balance closure within 2%.
Increment process channel velocity through 0.20, 0.30, 0.40, 0.50, and 0.60 m/s, recording steady-state temperatures and pressure drops at each plateau.
Calculate overall heat transfer coefficient U, plot U versus (v_p)^0.65, and fit a linear regression through the origin to evaluate S.
Points are your recorded observations. The solid regression line validates Plate Heat Exchanger mathematical scaling.
| # | Process Stream Velocity v_p (m/s) | Overall Conductance U (W/(m^2·K)) | Velocity factor (v_p)^0.65 ((m/s)^0.65) | Overall heat transfer coefficient U (W/(m^2·K)) | Remove |
|---|
No readings yet. Execute a process trial and record it.
In food processing, pharmaceuticals, biochemical manufacturing, and specialty chemical synthesis, gasketed plate-and-frame heat exchangers (PHEs) have largely superseded traditional shell-and-tube units for low-to-medium pressure duties. A plate heat exchanger consists of a pack of corrugated thin stainless steel or titanium plates compressed between a fixed head and movable follower frame. Elastomeric gaskets seal the plate perimeters and direct hot and cold fluids into alternate narrow inter-plate channels in true counter-current flow. The defining feature of PHEs is the chevron (herringbone) surface corrugation pressed into each plate. Adjacent plates are inverted so that corrugation ridges cross, forming a complex three-dimensional network of intersecting tortuous channels. These corrugations induce continuous swirling vortex shedding and boundary layer disruption at Reynolds numbers as low as 50 to 100, transitioning into intense turbulence well below the Re = 2,300 threshold of smooth tubes. Consequently, plate heat exchangers achieve exceptionally high overall heat transfer coefficients U (often 3 to 5 times greater than tubular exchangers), allowing extremely close temperature approaches (less than 1 °C) and compact footprints. In this experiment, an instrumented 10-plate chevron heat exchanger is operated across channel velocities from 0.10 to 0.60 m/s to quantify overall conductance U and verify empirical power-law velocity scaling U = S · v_p^0.65.
Evaluated using a 10-plate stainless steel PHE (plate width 100 mm, length 300 mm, chevron angle β = 60°, total active area A = 0.240 m^2). Linear regression models U versus (v_p)^0.65.