Constant-Voltage Exosomatic EDA Circuit
Applies strictly constant 0.500 V DC across electrodes and converts current to voltage (1.0 V / 10 μS).
Measure skin conductance level (SCL) and phasic skin conductance responses (SCR) across calibrated psychological arousal stimuli using constant-voltage DC bridge circuitry. Explore interactive physiological instrumentation simulation, biomechanics, and biomedical engineering telemetry.
Ready to sample with Arousal I = 3.0 units.
Adjust Arousal I, then execute biomedical trial.
Biomedical engineering telemetry and physiological states are evaluated rigorously using 64-bit IEEE 754 precision. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support high-fidelity biological and physiological modeling.
The linear arousal model applies across sub-saturation sensory intensities (1.0 to 6.0 units). Evaluated using two un-gelled Ag/AgCl palmar finger electrodes on the distal phalanges of the index and middle fingers with constant 0.500 V DC excitation. Phasic conductance response ΔG is evaluated across calibrated acoustic startle stimulus intensities from 1.0 to 6.0 arbitrary arousal units.
Applies strictly constant 0.500 V DC across electrodes and converts current to voltage (1.0 V / 10 μS).
Constructed with 1.0 cm² Ag/AgCl contact plates without gel to avoid artificial skin hydration.
Delivers calibrated white-noise acoustic tone bursts across six standardized intensity levels.
Samples conductance waveforms with 24-bit resolution and optical isolation compliant with IEC 60601-1.
Logs room ambient conditions (22.0 °C, 45% RH) to verify stable baseline perspiration.
Extracts tonic SCL baseline, peak SCR latency, and phasic amplitude ΔG in microsiemens.
Measure skin conductance level (SCL) and phasic skin conductance responses (SCR) across calibrated psychological arousal stimuli using constant-voltage DC bridge circuitry. Standardized parameter settings: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0 units.
Attach Ag/AgCl electrodes to the palmar surface of the distal phalanges of fingers II and III; allow 10 minutes for baseline thermal acclimation.
Verify with precision DMM that circuit applies exactly 0.500 V DC across the finger electrodes without voltage droop.
Record resting tonic conductance for 2 minutes to confirm a stable baseline (typically 2.0 to 10.0 μS) and absence of spontaneous spikes.
Deliver the initial acoustic stimulus (Level 1.0); identify the phasic SCR wave occurring 1.5 to 2.5 seconds post-stimulus.
Compute peak phasic conductance increase ΔG = G_peak - G_onset in microsiemens (μS).
Deliver stimuli of intensities 2.0, 3.0, 4.0, 5.0, and 6.0 at randomized 45-second intervals, plotting ΔG against stimulus level to determine k_g.
Points are your recorded observations. The solid regression line validates Galvanic Skin Conductance mathematical scaling.
| # | Stimulus Arousal Intensity I_stim (units) | Phasic Conductance Change ΔG (μS) | Stimulus intensity index (units) | Phasic skin conductance ΔG (μS) | Remove |
|---|
No readings yet. Execute a biomedical trial and record it.