Servohydraulic Biomechanical Testing Frame
Applies controlled uniaxial tensile displacement at constant strain rates with closed-loop actuator control.
Determine the longitudinal Young's modulus of cortical bone specimens loaded in uniaxial tension using extensometer strain tracking in a physiological saline bath. Explore interactive physiological instrumentation simulation, biomechanics, and biomedical engineering telemetry.
Ready to sample with Strain ε = 3.0 mstrain.
Adjust Strain ε, then execute biomedical trial.
Biomedical engineering telemetry and physiological states are evaluated rigorously using 64-bit IEEE 754 precision. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support high-fidelity biological and physiological modeling.
The linear elastic Hookean model applies strictly to small strains (ε < 0.006); post-yield microcracking requires continuum damage mechanics. Evaluated on machined cortical bone test coupons (gauge length 25.0 mm, rectangular cross-section 4.0 mm × 2.0 mm) excised along the longitudinal diaphyseal axis. Tested in 37 °C phosphate buffered saline (PBS) at a quasi-static strain rate of 0.001 s⁻¹. Linear elastic slope E = 17.5000 GPa is determined over strains from 1.0 to 6.0 mstrain.
Applies controlled uniaxial tensile displacement at constant strain rates with closed-loop actuator control.
Tracks gauge-length marker displacements to 0.1 μm without contacting the delicate bone surface.
Maintains specimen hydration and physiological temperature to prevent tissue embrittlement.
Measures applied axial tensile force with 0.1% accuracy and sub-Newton resolution.
Prevents end-slip and minimizes stress concentration outside the calibrated gauge section.
Determines cross-sectional gauge dimensions (width and thickness) with 1 μm precision.
Determine the longitudinal Young's modulus of cortical bone specimens loaded in uniaxial tension using extensometer strain tracking in a physiological saline bath. Standardized parameter settings: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0 mstrain.
Retrieve machined longitudinal cortical bone specimen from -20 °C storage, thaw in PBS at 37 °C, and measure cross-sectional gauge dimensions with optical micrometer.
Mount the bone specimen in the mechanical testing collet grips, verify axial alignment to prevent bending moments, and zero the 5 kN load cell in the slack position.
Affix two high-contrast retro-reflective gauge markers 25.0 mm apart on the bone face and calibrate the video extensometer tracking algorithms.
Apply 10 cycles of triangular tensile preconditioning from 0 to 0.5 mstrain at 0.1 Hz to establish steady-state viscoelastic baseline.
Execute tensile loading ramp at 0.001 s⁻¹ through strain increments of 1.0, 2.0, 3.0, 4.0, 5.0, and 6.0 mstrain, logging load and extensometer strain at 100 Hz.
Convert load to engineering stress σ = F/A, plot σ versus strain ε, and calculate Young's modulus E from the slope of the linear elastic region.
Points are your recorded observations. The solid regression line validates Bone Tensile Elastic Modulus mathematical scaling.
| # | Longitudinal Tensile Strain ε (mstrain) | Tensile Stress σ (MPa) | Tensile strain ε (mstrain) | Tensile stress σ (MPa) | Remove |
|---|
No readings yet. Execute a biomedical trial and record it.