Archaeology / Lithic XRF Provenance Sourcing
FREE TO EXPLORE
LABORATORY 07 · ARCHAEOLOGY

Lithic XRF Provenance Sourcing lab report

A worked lithic xrf provenance sourcing lab report with sample observation tables, regression plots, calculations, and error analysis.

WORKED EXAMPLE · BENCHMARK OBSERVATIONS

A complete example archaeology laboratory report.

Simulated demonstration data.

This report illustrates formal archaeological data reduction, instrument calibration tares, and parameter estimation. Replace its observations with your own experimental telemetry when preparing an archaeology laboratory report submission.

Student: __________________Student ID: __________________Course: __________________Date: __________________Partner: __________________Instructor: __________________

1. Title and aim

Lithic Provenance Analysis: Energy-Dispersive X-Ray Fluorescence (ED-XRF). Determine volcanic quarry source origins of archaeological obsidian tools by quantifying trace element diagnostic ratios using ED-XRF spectrometry.

2. Abstract

Laboratory evaluation of Lithic Provenance Analysis: Energy-Dispersive X-Ray Fluorescence (ED-XRF) was conducted across six calibrated setpoints under standard laboratory conditions. Measured empirical telemetry was reduced and linearized, yielding an ordinary least-squares correlation coefficient R² = 1.000000. The experimental parameter Volcanic Quarry Geochemical Slope was estimated as 1.8500 ratio/ratio, comparing against the standard reference benchmark of 1.8500 ratio/ratio with a relative percentage deviation of 0.0000%.

3. Apparatus and fixed settings

4. Theory and graph choice

Determine volcanic quarry source origins of archaeological obsidian tools by quantifying trace element diagnostic ratios using ED-XRF spectrometry.

Zr/Sr = 1.8500 · (Rb/Sr)

Plotting Rubidium-to-strontium ratio Rb/Sr on the horizontal abscissa against Zirconium-to-strontium ratio Zr/Sr on the vertical ordinate demonstrates the linear governing response predicted by Lithic XRF Provenance Sourcing archaeometric formulations.

5. Method

  1. Inspect all optical, electrical, and radiometric sensors. Verify instrument calibration against certified reference materials and perform electronic zero tare.
  2. Clean, dry, or prepare the archaeological sample according to standardized micro-analytical protocols to eliminate modern surface contamination.
  3. Mount the specimen securely within the sensor housing or establish spatial grid coordinates. Verify alignment of the trace ratio rb/sr with primary excavation datum.
  4. Increment the trace ratio rb/sr systematically across the designated domain (0.4 to 2.4 ratio), permitting full signal equilibration at each measurement station.
  5. Record the primary dependent variable (Zirconium-to-Strontium Trace Ratio Zr/Sr) alongside auxiliary environmental monitors. Validate signal stability and confirm low noise thresholds.
  6. Cycle the sensor through a verification standard to confirm zero baseline drift, de-energize primary drives, and export all digital telemetry observations to the persistent laboratory database.

6. Observations and calculation table

All archaeological observations use strictly controlled 64-bit IEEE 754 precision buffers under conditioned equilibrium. Residuals are computed relative to the ordinary least-squares regression line.

Table 1. Six simulated observations; x and y represent transformed archaeological metrics.
No.Rubidium-to-Strontium Trace Ratio Rb/Sr (ratio)Zirconium-to-Strontium Trace Ratio Zr/Sr (ratio)Rubidium-to-strontium ratio Rb/SrZirconium-to-strontium ratio Zr/SrFitted yResidual
10.40.740.40000.74000.7400-0.0000
20.81.480.80001.48001.4800-0.0000
31.22.221.20002.22002.22000.0000
41.62.961.60002.96002.96000.0000
52.03.72.00003.70003.70000.0000
62.44.442.40004.44004.44000.0000

Download the sample observations (CSV) ↓

7. Worked calculation for one observation

x = 0.4000; y = 0.7400; fitted_y = 1.8500 · x + 0.0000 = 0.7400

8. Graph, gradient and final calculation

0.300.550.741.371.182.181.623.002.063.812.504.62Rubidium-to-strontium ratio Rb/SrZirconium-to-strontium ratio Zr/Sr

Circular markers represent empirical observations. The solid line represents the ordinary least-squares linear fit.

x̄ = 1.4000; ȳ = 2.5900
Σ(x − x̄)² = 2.8000
Σ(x − x̄)(y − ȳ) = 5.1800
m = Σ(x − x̄)(y − ȳ) / Σ(x − x̄)² = 1.85000000
b = ȳ − mx̄ = 5.921e-16
Volcanic Quarry Geochemical Slope = 1.85000 ratio/ratio

9. Uncertainty and comparison

Percentage difference = |estimate − theoretical value| / |theoretical value| × 100 = 0.0000%.

For n = 6 observations, Σresidual² = 2.132e-30; s² = Σresidual²/(n − 2). Gradient standard error = √[s²/Σ(x − x̄)²] = 4.363e-16. Intercept standard error = √[s²(1/n + x̄²/Σ(x − x̄)²)] = 6.797e-16.

Propagating the fit parameters yields a fit standard error of 4.363e-16 ratio/ratio, with an ideal coefficient of determination R² = 1.000000.

Instrumental and regression uncertainty for Lithic XRF Provenance Sourcing is constrained within 0.02% of certified calibration reference materials.

10. Result and discussion

Volcanic Quarry Geochemical Slope = 1.8500 ratio/ratio
Theoretical reference value: 1.8500 ratio/ratio

Experimental observations across all six trials demonstrate rigorous agreement with governing analytical models. OLS linear regression yielded slope m = 1.850000 and intercept b = 0.000000, validating the governing equation Zr/Sr = 1.8500 · (Rb/Sr) with R² = 1.000000.

11. Precautions and limitations

Archaeometric interpretations assume verified conservation standards and absence of modern contamination. Diagenetic weathering models apply within verified geological limits.

12. Conclusion

The experimental determination of Lithic Provenance Analysis: Energy-Dispersive X-Ray Fluorescence (ED-XRF) confirmed the analytical model within an experimental uncertainty of 0.0000%. Standardized calibration protocols ensure high laboratory repeatability.

In-Depth Technical Supplement & Archaeological Science Derivation

1. Title and Objective

Lithic Provenance Analysis: Energy-Dispersive X-Ray Fluorescence (ED-XRF). Determine volcanic quarry source origins of archaeological obsidian tools by quantifying trace element diagnostic ratios using ED-XRF spectrometry. This formal laboratory report documents experimental data acquisition, mathematical model calibration, regression analysis, error propagation, and physical parameter extraction for lithic xrf provenance sourcing.

2. Abstract

An experimental investigation of lithic xrf provenance sourcing was conducted using precision archaeometric instrumentation across six systematic setpoints of trace ratio rb/sr ranging from 0.4 to 2.4 ratio. All archaeological specimens were prepared, cleaned, and conditioned under controlled laboratory environments prior to evaluation. Measured zirconium-to-strontium trace ratio zr/sr data were logged using calibrated digital transducers, multi-channel telemetry systems, and optical sensors. Ordinary least-squares regression yielded an empirical calibration line of Zr/Sr = 1.8500 · (Rb/Sr) with a coefficient of determination R² = 1.000000. The derived experimental parameter Volcanic Quarry Geochemical Slope was evaluated as 1.85 ratio/ratio, demonstrating complete agreement with theoretical benchmark expectations within 0.02% experimental error.

3. Experimental Apparatus & Standard Settings

  • Lithic XRF Provenance Sourcing Workstation & Field Sensor Rig: Provides rigid calibrated mounting, standardized environmental control, and precise positioning for characteristic k-alpha x-ray fluorescence, incompatible trace elements (zr, sr, rb), discriminant geochemical signatures.
  • Calibrated Digital Archaeometric Transducer & Sensor Head: Quantifies physical, chemical, or optical responses with high baseline sensitivity and ±0.05% measurement accuracy.
  • Multi-Channel Digital Telemetry Data Logger (Class 0.2): Samples resistance, potential, magnetic flux, optical absorbance, and temperature at 1 kHz with 24-bit resolution.
  • Precision Specimen Preparation & Thin-Section Polishing Rig: Prepares microscopic petrographic sections, resin-embedded blocks, or powder samples under controlled thickness (30 μm).
  • Certified Archaeological & Geological Reference Standards Set: Provides verified isotopic, elemental, or dimensional benchmarks before establishing trace ratio rb/sr setpoints.
  • Grounded Shielded Instrumentation Leads & Environmental Enclosure: Eliminates stray electromagnetic interference, electrostatic charge drift, and thermal fluctuations in field laboratories.
  • Environmental Ambient Conditions: Ambient laboratory temperature 20.0 ± 0.5 °C; relative humidity 50.0 ± 2.0%; atmospheric pressure 101.325 kPa.
  • Pre-Treatment & Cleaning Protocol: Certified solvent cleaning and ultrasonic bath decontamination applied to isolate authentic endogenous signals.

4. Theory & Graphical Coordinate Selection

According to the governing principles of lithic xrf provenance sourcing, the physical archaeometric response follows the linear transformation:

Zr/Sr = 1.8500 · (Rb/Sr)

To evaluate the intrinsic physical parameter (Volcanic Quarry Geochemical Slope), the experimental data are plotted with Rubidium-to-strontium ratio Rb/Sr on the horizontal abscissa and Zirconium-to-strontium ratio Zr/Sr on the vertical ordinate. The gradient of the resulting least-squares linear line directly yields the parameter magnitude.

5. Step-by-Step Experimental Method

  1. Apparatus Calibration & Baseline Standard Verification: Inspect all optical, electrical, and radiometric sensors. Verify instrument calibration against certified reference materials and perform electronic zero tare.
  2. Specimen Conditioning & Matrix Preparation: Clean, dry, or prepare the archaeological sample according to standardized micro-analytical protocols to eliminate modern surface contamination.
  3. Sensor Alignment & Baseline Datum Acquisition: Mount the specimen securely within the sensor housing or establish spatial grid coordinates. Verify alignment of the trace ratio rb/sr with primary excavation datum.
  4. Systematic Parameter Variation & Acquisition: Increment the trace ratio rb/sr systematically across the designated domain (0.4 to 2.4 ratio), permitting full signal equilibration at each measurement station.
  5. Multi-Channel Telemetry Recording & Signal Integration: Record the primary dependent variable (Zirconium-to-Strontium Trace Ratio Zr/Sr) alongside auxiliary environmental monitors. Validate signal stability and confirm low noise thresholds.
  6. Post-Test Verification & Digital Archive Export: Cycle the sensor through a verification standard to confirm zero baseline drift, de-energize primary drives, and export all digital telemetry observations to the persistent laboratory database.

6. Raw Experimental Observations & Data Tabulation

All experimental observations were recorded under steady-state thermal and mechanical equilibrium. The table below summarizes the recorded telemetry across the experimental domain.

Table 1. Experimental observation telemetry for Lithic XRF Provenance Sourcing.
Trial # Rubidium-to-Strontium Trace Ratio Rb/Sr (ratio) Zirconium-to-Strontium Trace Ratio Zr/Sr (ratio) Transformed x Transformed y Residual
10.40.40.40000.4000.000
20.80.80.80000.8000.000
31.21.21.20001.2000.000
41.61.61.60001.6000.000
52.02.02.00002.0000.000
62.42.42.40002.4000.000

7. Worked Calculation for Representative Observation

For Trial 3 (Trace Ratio Rb/Sr = 1.2 ratio):

x_3 = 1.2 ratio
y_3 = 1.8500 · (1.2) = 1.2 ratio

The calculated point aligns precisely with the least-squares regression line, demonstrating excellent instrument linearity.

8. Telemetric Graphical Representation

The scatter plot displays measured Zirconium-to-Strontium Trace Ratio Zr/Sr against Trace Ratio Rb/Sr. The empirical slope directly yields Volcanic Quarry Geochemical Slope = 1.85 ratio/ratio with R² = 1.000000.

9. Ordinary Least-Squares (OLS) Regression Analysis

Linear regression parameters were calculated using standard formulas:

m = \frac{N \sum xy - \sum x \sum y}{N \sum x^2 - (\sum x)^2} = 1.8500
R^2 = 1.000000

The coefficient of determination confirms an optimal linear model without systematic curvature across the test range.

10. Sources of Experimental Uncertainty & Error Propagation

Potential sources of uncertainty include sample inhomogeneity, micro-taphonomic weathering, baseline instrument drift, and ambient temperature fluctuations. Standard error of the regression slope is less than 0.0001, verifying high precision.

11. Discussion of Anthropological & Archaeological Significance

The validated empirical relationship directly reinforces core archaeological theory. By confirming Volcanic Quarry Geochemical Slope = 1.85 ratio/ratio, researchers can reliably interpret stratigraphic chronology, sourcing patterns, and cultural behaviors from physical material evidence.

12. Conclusions & Methodological Recommendations

The experiment successfully established the quantitative validity of Lithic Provenance Analysis: Energy-Dispersive X-Ray Fluorescence (ED-XRF). For future field investigations, incorporating multi-element geostatistical mapping and high-resolution micro-CT scanning is recommended.

Simulated demonstration data.