Psychrometric Air-Conditioning Tunnel
Includes variable-speed fan, electric heating elements, steam humidifier, and measurement stations.
Determine the sensible heat transfer, moisture carrying capacity, and psychrometric drying potential of heated air across deep grain beds using psychrometric enthalpy balances. Explore interactive farm machinery simulation, irrigation hydraulics, and agricultural engineering telemetry.
Ready to sample with Air Temp T_db = 49.0 °C.
Adjust Air Temp T_db, then execute agricultural trial.
Agricultural engineering telemetry and biosystems states are evaluated rigorously using 64-bit IEEE 754 precision. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support high-fidelity agricultural and environmental modeling.
Assumes ideal adiabatic drying conditions; heat losses through uninsulated duct walls cause slight departures from constant enthalpy lines. Evaluated at ambient intake air conditions of 20°C dry-bulb and 60% RH (ambient humidity ratio W_in = 8.8 g/kg dry air) across drying temperatures from 35°C to 70°C.
Includes variable-speed fan, electric heating elements, steam humidifier, and measurement stations.
Measures dry-bulb (T_db) and wet-bulb (T_wb) temperatures with 0.1°C matched thermistors.
Logs dew point, absolute humidity ratio W, and relative humidity across duct stations.
Standard test bed of moist corn through which conditioned air percolates.
Measures airflow static resistance and Shedd's curve pressure drop (Pa/m).
Measures total air mass flow rate m_dot_air (kg/s) with 1.0% accuracy.
Determine the sensible heat transfer, moisture carrying capacity, and psychrometric drying potential of heated air across deep grain beds using psychrometric enthalpy balances. Standardized parameter settings: 35.0, 42.0, 49.0, 56.0, 63.0, 70.0 °C.
Record ambient air dry-bulb temperature (20.0°C) and relative humidity (60.0%), calculating baseline humidity ratio W_in = 8.80 g H₂O/kg dry air from psychrometric relations.
Set duct air velocity to 0.4 m/s through the grain column, powering the heating stage to achieve initial dry-bulb temperature T_db = 35.0°C.
Verify that absolute humidity ratio W upstream of the grain bed matches ambient W_in, confirming pure sensible heating without moisture addition.
Measure exhaust air wet-bulb and dry-bulb temperatures downstream of the grain bed, determining saturation humidity ratio W_sat at the adiabatic wet-bulb temperature.
Increment heater temperature in five uniform stages to 42, 49, 56, 63, and 70°C, recording steady-state inlet and outlet psychrometric states for each run.
Calculate evaporative capacity ΔW = W_sat - W_in for each temperature, plot ΔW versus T_db, and determine the thermal drying sensitivity gradient s_dp.
Points are your recorded observations. The solid regression line validates Air-Grain Psychrometrics mathematical scaling.
| # | Heated Drying Air Dry-Bulb Temperature T_db (°C) | Drying Potential Evaporative Capacity ΔW (g/kg) | Drying air temperature T_db (°C) | Evaporative capacity ΔW (g H₂O/kg dry air) | Remove |
|---|
No readings yet. Execute an agricultural trial and record it.